Colonic perforation due to impacted biliary stent

Authors

DOI:

https://doi.org/10.30944/20117582.2313

Keywords:

choledocholithiasis, endoscopic retrograde cholangiopancreatography, prostheses and implants, intestinal perforation, surgical procedures

Abstract

Introduction. Endoscopic placement of biliary stents is becoming more common every day, as it is currently one of the best options for the treatment of bile duct pathologies. One of the complications that can occur is the migration of the endoprostheses in up to 10.8% of patients, which in very rare cases can cause intestinal perforation.

Clinical case. This is a 61-year-old female patient, who underwent endoscopic retrograde cholangiopancreatography five years ago for choledocholithiasis. She consulted due to abdominal pain, with a physical examination that upon palpation documented an acute abdomen and a palpable plastron in the left iliac fossa. The computed tomography revealed a foreign body at the level of the descending colon, with perforation. Exploratory laparotomy and colostomy were performed due to perforation of the sigmoid colon secondary to migrated biliary prosthesis.

Results. The patient progressed favorably and six months later the colostomy was closed without complications.

Conclusions. Patients who receive biliary stents require adequate follow-up to avoid complications that, although rare, may occur, such as intestinal migration with intestinal perforation. The treatment of these complications can be endoscopic, laparoscopic or laparotomy in case of severe complication.

Downloads

Download data is not yet available.

Author Biographies

Abraham Hernán Herrera-Sánchez, Hospital general Dr. Agustín O`Horán, Yucatán, México.

Servicio de cirugía general.

Shadid A. Rodríguez-Gómez, Hospital general Dr. Agustín O`Horán, Yucatán, México.

Servicio de cirugía general.

Ricardo E. E. Chacón, Hospital general Dr. Agustín O`Horán, Yucatán, México.

Servicio de cirugía general.

References

Goñi HB, Cusihuallpa JA, Beraún NM, Moscol MD, Calderón AV, Salas FP, et al. Seguridad y eficacia del uso de prótesis metálicas autoexpandibles en el manejo de estenosis malignas de la vía biliar irresecables. Rev Gastroenterol Perú. 2019;39:116-22.

Castaño R, Álvarez Ó, Lee JK, Lopera J, Calvo V. Un nuevo prototipo de stent biliar cubierto (flower stent) frente al stent biliar convencional en la prevención de pancreatitis y colecistitis poststent. Rev Colomb Gastroenterol. 2018;33:393-403. https://doi.org/10.22516/25007440.312

Oregel-Aguilar V, Herrera-Servín MA, Galvis-García SE, Ornelas-Escobedo E, Torreblanca-Sierra LF, Silis-Clavioto JC, et al. Manejo endoscópico de prótesis biliares con migración proximal experiencia Hospital General de México. Endoscopia. 2020;32:297.

Anderson EM, Phillips-Hughes J, Chapman R. Sigmoid colonic perforation and pelvic abscess complicating biliary stent migration. Abdom Imaging. 2007;32:317- 9. https://doi.org/10.1007/s00261-006-9067-2

Jadallah K, Alzubi B, Sweidan A, Almanasra AR. Intraperitoneal duodenal perforation secondary to early migration of biliary stent: closure with through-the-scope clip. BMJ Case Rep. 2019;12:e230324. https://doi.org/10.1136/bcr-2019-230324

Ross E, McKenna P, Anderson JH. Foreign bodies in sigmoid colon diverticulosis. Clin J Gastroenterol. 2017;10:491-7. https://doi.org/10.1007/s12328-017-0786-4

Park TY, Hong SW, Oh HC, Do JH. Colonic diverticular perforation by a migrated biliary stent: A case report with literature review. Medicine. 2021;100:e28392. https://doi.org/10.1097/MD.0000000000028392

Kim SH, Moon JH, Lee YN, Lee TH, Woo SM, Lee WJ, et al. Endoscopic management of duodenal perforations caused by migrated biliary plastic stents. Endosc Int Open. 2019;7:792-5. https://doi.org/10.1055/a-0887-4200

Culnan DM, Cicuto BJ, Singh H, Cherry RA. Percutaneous retrieval of a biliary stent after migration and ileal perforation. World J Emerg Surg. 2009;4:1-5. https://doi.org/10.1186/1749-7922-4-6

Wael M, Mohamed A, Vinay J, Ifrah F, Fouad S, Noor H, et al. Rates of retained biliary stents could be affected by socioeconomic status and language barrier. Am J Gastroenterol. 2022;117:e36. https://doi.org/10.14309/01.ajg.0000856832.86656.0d

Siiki A, Sand J, Laukkarinen J. A systematic review of biodegradable biliary stents: promising biocompatibility without stent removal. Eur J Gastroenterol Hepatol. 2018;30:813-8. https://doi.org/10.1097/MEG.0000000000001167

Published

2024-01-02

How to Cite

(1)
Herrera-Sánchez, A. H.; Rodríguez-Gómez, S. A.; E. Chacón, R. E. Colonic Perforation Due to Impacted Biliary Stent. Rev Colomb Cir 2024, 39, 168-172.

Issue

Section

Presentación de Caso

Altmetric

Escanea para compartir
QR Code
Article metrics
Abstract views1275
Galley views357
PDF Views357
HTML views0
Other views0

Some similar items: