Use of polypropylene meshes in the repair of inguinal hernia with dirty or contaminated wound
DOI:
https://doi.org/10.30944/20117582.585Keywords:
hernia, inguinal, herniorrhaphy, surgical mesh, prostheses and implants, intestine, small, surgical woundAbstract
Introduction: Polypropylene mesh hernioplasty is the technique of choice for the repair of inguinal hernias. Currently, there is controversy about this technique in patients with dirty or contaminated wounds. However, evidence in the medical literature has shown its use can be safe. The authors present their experience in the use of polypropylene meshes in contaminated surgery to close inguinal hernias.
Methods: A retrospective observational study was conducted in patients older than 18 year-old between January 2017 and December 2018. Were included those with inguinal hernias, requiring emergency surgical treatment, and presented contaminated or dirty wounds. The inclusion criteria were infection of the surgical wound, the need for removal of the mesh removal and recurrence of the hernia.
Results: Ten patients underwent emergency surgery, requiring bowel resection for necrosis: nine of them for strangulated hernias and, one for perforated appendicitis. In one of the ten patients, the wound was considered dirty due to intestinal necrosis and perforation. The remaining nine had intestinal necrosis without perforation, so they were considered contaminated wounds. Wound infection occurred in 1/10 patients (10%) with superficial operative site infection; mesh removal was not necessary in any patient during the entire study period. No recurrence was observed and there was no mortality.
Conclusion: The use of polypropylene mesh for the correction of inguinal hernias in patients with contaminated and dirty wounds is effective and safe, with acceptable morbidity and good short-term results.
Downloads
References
2. Lockhart K, Dunn D, Teo S, Ng JY, Dhillon M, Teo E, et al. Mesh versus non-mesh for inguinal and femoral hernia. Cochrane Database Syst Rev. 201813;9:CD011517. https://doi.org/10.1002/14651858.CD011517.pub2.
3. Simons MP, Smietanski M, Bonjer HJ, Bittner R, Miserez M, Aufenacker TJ, et al. International guidelines for groin hernia management. Hernia. 2018;22:1-165.
https://doi.org/10.1007/s10029-017-1668.
4. Nyhus LM. Iliopubic tract repair of inguinal and femoral hernia: The posterior (preperitoneal) approach. Surg Clin North Am. 1993;73:487-99
https://doi.org/10.1016/S0039-6109(16)46032-9.
5. Gopal SV, Warrier A. Recurrence after groin hernia repair-revisited. International J Surg. 2013;11:374e-7.
https://doi.org/10.1016/j.ijsu.2013.03.012
6. Matthews RD, Neumayer L. Inguinal hernia in the 21st century: An evidence-based review. Curr Probl Surg. 2008;45:261-312.
https://doi.org/10.1067/j.cpsurg.2008.01.002.
7. Rosen MJ, Krpata DM, Ermlich B, Blatnik JA. A 5-year clinical experience with single-staged repairs of infected and contaminated abdominal wall defects utilizing biologic mesh. Ann Surg. 2013;257:991-6.
https://doi.org/10.1097/SLA.0b013e3182849871.
8. Hentati H, Dougaz W, Dziri C. Mesh repair versus non-mesh repair for strangulated inguinal hernia: Systematic review with meta-analysis. World J Surg. 2014;38:2784-90. https://doi.org/10.1007/s00268-014-2710-0.
9. Kuckelman JP, Barron MR, Blair K, Martin MJ. The routine use of prosthetic mesh in austere environments: Dogma vs data. Am J Surg. 2016;211:958-62. https://doi.org/10.1016/j.amjsurg.2016.02.005.
10. Pandey H, Thakur DS, Somashekar U, Kothari R, Agarwal P, Sharma D. Use of polypropylene mesh in contaminated and dirty strangulated hernias: Short-term results. Hernia. 2018;22:1045-50. https://doi.org/10.1007/s10029-018-1811-3.
11. Tastaldi L, Krpata DM, Prabhu AS, Petro CC, Ilie R, Haskins IN, et al. Emergent groin hernia repair: A single center 10-year experience. Surgery. 2019;165:398-405. https://doi.org/10.1016/j.surg.2018.08.001.
12. Montejo JE, Pisonero JJ, Delgado AD. Uso de malla de polipropileno en la hernioplastia por técnica de Lichtenstein. Revista Cubana de Cirugía. 2011;50:147-54.
Downloads
Published
How to Cite
Issue
Section
License
Todos los textos incluidos en la Revista Colombiana de Cirugía están protegidos por derechos de autor. Las opiniones expresadas en los artículos firmados son las de los autores y no coinciden necesariamente con las de los directores o los editores de la Revista Colombiana de Cirugía. Las sugerencias diagnósticas o terapéuticas como elección de productos, dosificación y métodos de empleo corresponden a la experiencia y al criterio de los autores.
| Article metrics | |
|---|---|
| Abstract views | 27052 |
| Galley views | 1494 |
| PDF Views | 1494 |
| HTML views | 0 |
| Other views | 0 |












.jpg)